Problem Solution

JDCBEND TROUBLE SHOOTING GUIDE

Trouble Shooting Guide
The easiest way to fix electrical problems is to order a replacement electrical module from the JDC manufacturer. This is supplied on an exchange basis and therefore is quite reasonably priced.

Before sending for an exchange module you may like to check the fllowing:

If the machine does not operate at all:
a) Check that power is available at the machine by obsering the pilot light in the ONOFF swich.
b) If power is available but the machine is sill dead but fels very hot then the thermal cut-out may have tipped. In this case wait until the machine cools down (about % an hour) and then try it again.
c) The two-handed starting interlock requires that the START button is pressed before the handle is pulled. If the handle is pulled first then the machine will not operate. Also it may happen that the bending beam moves (or is bumped) sufficiently to operate the "angle microswitch" before the START buton is pressed. If this happens make sure the handle is pushed fully back first. If this is a persistent problem then it indicates that the microswitch actuator needs adjustment (see below).
d) Another possibility is that the START button may be faulty. If you have a Model 1250E or larger then sce if the machine can be started with one of the alternative START buttons or the footswitch.

jdcbend-trouble-shooting-guide-1

e) Also check the nylon connector which connects the electrical module with the magnet coil.
f) If clamping does not operate but the clampbar snaps down on release of the START button then this indicates that the 15 microfarad (10 μuF on the 650E) capacitor is faulty and will need to be replaced.
g) If the machine blows extermal fuses or trips cireuit breakers when operated then the most likely eause is a blown bridge- retifier. Make sure that the machine is unplugged from the power outlet before atempting internal repairs.

A suitable replacement rectifier ;
RS Components part number: 227-8794
Max current: 35 amps continuous,
Max reverse voltage: 1000 Volts,
Terminals: 14" quick conncct or "Faston'
Approx price: $12.00 Bridge rectifier image

jdcbend-trouble-shooting-guide-2

If light clamping operates but full clamping does not:
Check that the "Angle Microswitch" is being actuated corretly.

This switch is operated by a square (or round) brass piece which is atached to the angle indicating mechanism.When the handle is pulled the bending beam rotates which imparts a rotation to the brass actuator. The actuator in turn operates a microswitch inside the electrical assembly.

Switch actuator
Microswitch actuator on the Model 1000E
(Other models use the same principle)
Actuator from inside
Actuator as seen from inside the electrical
assembly.

jdcbend-trouble-shooting-guide-22

Pull the handle out and in. You should be able to hear the microswich clicking ON and OFF (provided there is not too much background noise).
If the switch does not click ON and OFF then swing the bending beam right up so that the brass actuator can be observed. Rotate the bending beam up and down. The actuator should rotate in response to the bending beam (until it clutches at its stops)- If it does not then it may need more clutching force. On the 1250E lack of clutching force usually relates to the two M8 cap-head screws at cither end of the actuator shaft not being tight. If the actuator rotates and clutches OK but still does not click the microswitch then it may need adjusting. To do this first unplug the machine from the power outlet and then remove the electrical access panel.

a) On the Model 1250E the turn-on point can be adjusted by tuming a screw which passes through the actuator. The screw should be adjusted such that the switch clicks when the bottom edge of the bending beam has moved about 4 mm. (On the 650E and 1000E the sane adjustment is achieved by bending the arm of the microswitch.)

b) If the microswitch does not click ON and OFF even though the actuator is working properly then the switch itself may be fused inside and will need to be replaced.
Make sure that the machine is unplugged from the power outlet before atempting internal repairs.

V3 microswitchA suitable replacement V3 switch:
RS part number: 472-8235
Current rating: 16 amps
Voltage rating: 250 Volts AC
Lever type: long

jdcbend-trouble-shooting-guide-3

c) If your machine is ftted with an auxilary switch then make sure it is swiched to the "NORMAL" position. (Oaly light clamping will be available if the switch is in the "AUX CLAMP" position)

If clamping is OK but Clampbars do not release when the machine switches OFF:
This indicates a failure of the reverse pulse demagnetising circuit. The most likely cause would be a blown 6.8 ohm power resistor. Also check all diodes and also the possbility of sticking contacts in the relay.
Make sure that the machine is unplugged from the power outle before atempting intermal repairs.

Wirewound resistorA suitable replacement resistor:
Element14 part No.145 7941
6.8 ohm, 10 watt power rating,
Typical cost S1.00

jdcbend-trouble-shooting-guide-4

If machine will not bend heavy gauge sheet:
a) Check that the job is within the speeifeations of the machine. In particular note that for 1.6 mm (16 gauge) bending the extension bar must be ftted to the bending beam and that the minimum lip width is 30 mm. This means that at least 30 mm of material must project out from the bending edge of the clampbar. (This applies to both aluminium and see.)

Narrower lips ane possible if the bend is not the full length of the machine.

b) Also if the workpiece does not fill up the space under the clampbar then performance may be afected. For best results always fill up the space under the clampbar with a scrap piece of steel the same thickness as the workpiece. (For best magnetic clamping the fller piece should be steel even if the workpiece is not steel)

This is also the best method to use if it is required to make a very narrow lip on the workpiece.

jdcbend-trouble-shooting-guide-5